DATA SETTING
GYRO SENCE
01 . MODEL-01. NORML HEL PCM 0: 23: 17
DUAL : MODE
: GAIN 1
: GAIN 2
0 20 40 60 80 100
END
85 %
15 %
85%
15%
GAIN1
setting
GAIN2
setting
70%
30%
AVCS side
Normal side
70% 40%
(Setting Example)
Adjust the gyro gain at the Gyro Sense Mixing setup screen at each
condition.
The following shows a setting example in the CMT mode.
Select the Dual Mode (DUO).
Sensitivity rate
Choose the GAIN1 or GAIN2 by the CH5 switch.
Use the following values as the sensitivity setting standard:
CH5 switch
Actual gain
Hovering Flight
The GY601 sensitivity is 0% at 50%. When set over 50%, the GY601
operates in the AVCS mode and when set under 50%, the GY601
operates in the Normal mode. When setting is changed 1%, the gyro
sensitivity is changed 2%.