Seitenansicht 28
29
D
ATA
S
ETTING
When Using a GY611 Gyro Gain Adjustment Function
[Transmitter Settings]
Adjust both the End Point (ATV) rates to 90% at the transmitter remote gain
channel (CH5, etc.) End Point (ATV) function.
[GY611 Settings]
Operation Mode Setting function:
Select the gyro operation mode at the GY611 Mode screen. (AVC, NOR, or
CMT)
Gyro Gain Adjustment function:
Set the G:1 and G:2 gains at the GY611 G:x screen.
[Relationship between transmitter and gyro setting]
Transmitter settings:
End Point (ATV) rates
Switch Switch
Forward side Front side
90% (Fixed) 90% (Fixed)
Normal mode
AVCS mode
Normal mode AVCS mode
(G2) (G1)
GY611 adjusting
range: 100% - 0% - 100%
NOR:
AVC:
CMT:
GY611 mode
settings: